Error Management
The Error Management window identifies and (where possible) corrects logical errors that may arise during project design.
Tabs
- Errors: Lists all detected project errors with columns for No., Description, Page, and Coordinate.
- Settings: Select which error types to display. Use Check all or Uncheck all for bulk selection.
The [Edit] Button
Allows you to collectively change or correct errors on selected lines based on common element properties.
COFASO Error Types (39 Total)
| No. | Description |
|---|---|
| 1 | Potential-arrow pair in wrong direction |
| 2 | Cable for not allowed type or shielding |
| 3 | Cable with not enough conductors |
| 4 | Too many entries for terminal plan area |
| 5 | Contact without a main element |
| 6 | Not defined connector |
| 7 | Terminal strip name not defined |
| 8 | Terminal used too many times |
| 9 | Cable conductors not suitable for PE/N |
| 10 | Connection designations missing |
| 11 | Cable shielding ends not connected to PE or Ground |
| 12 | Contactor without any used contacts |
| 13 | PE/N terminal not connected to PE |
| 14 | Duplicate designation |
| 15 | Wrong symbol type for socket |
| 16 | One/two ends of terminal not used |
| 17 | Unused cable conductors |
| 18 | Parts without price |
| 19 | Terminal jumping without predefined jumper property |
| 20 | Jumping between terminals of different strips |
| 21 | Missing pair of potential-arrow |
| 22 | Device without part |
| 23 | Plug has not enough contacts/pins |
| 24 | Cable has more than one PE/N conductor |
| 25 | Cable has total shielding only, not for conductors |
| 26 | Cable can have only 1 PE conductor |
| 27 | Cable can have only 1 N conductor |
| 28 | Cable can have only 1 SH conductor |
| 29 | Unused conductors on the cable |
| 30 | Terminal does not match conductor of cable (PE terminal to PE) |
| 31 | Shielding cannot be connected to SH in a cable |
| 32 | Cable type and used conductors do not match |
| 33 | Duplicate connection designation |
| 34 | Same terminal number used more than once |
| 35 | More than one shielding |
| 36 | Motor-protection-relay without contacts |
| 37 | Potential-arrow pair not found |
| 38 | Contactor not current — used and available contacts differ |
| 39 | Used symbol does not match contactor's cross-referenceable contacts |
Notes
- Corrected errors are automatically removed from the list.
- Double-click an error line to jump directly to the element with the error.
- Keep the Error Management window open while correcting elements.